How To Choose A Dual Chamber Unit For A Lab

Alsin Technology Services · Updated 22 November 2026

A dual chamber unit puts two independent chambers in one instrument, one above the other. Each chamber has its own temperature control and its own door. These steps help you pick the right pair.

1. Decide What Each Chamber Will Do

Each chamber can be a refrigerator (2 to 8 °C), a freezer (−20 °C), a stability chamber (20 to 60 °C, with humidity from ambient to 90 % RH) or a BOD incubator (10 to 60 °C). The combinations the catalogue shows are below. Ask us if you need another pairing.

Top chamberBottom chamber
RefrigeratorRefrigerator
RefrigeratorFreezer (−20 °C)
Freezer (−20 °C)Freezer (−20 °C)
Stability chamberStability chamber
BOD incubatorBOD incubator

2. Pick The Capacity

The chambers come in 120 L and 210 L sizes. Count what you need to store or incubate in each chamber, then ask us which size pair fits.

3. Check The Controls And Doors

Each chamber has an individual temperature control and its own door, and the dual door design helps each chamber retain its temperature. Resolution is 0.1 °C and accuracy is ±1 °C, or ±3 % RH for the stability chamber. The freezer chamber has a defrost cycle you can set, up to one month. A safety door sensor cuts off operation to retain the temperature inside the chamber.

4. Choose Between The Pt Series And The Au Series

  • Pt Series highlights: 7 inch TFT colour touch display, 5-channel data recording with mapping, password-protected door lock and a UPS line for the controller.
  • Au Series highlights: LCD display with 21 CFR compliance software, email alarm notifications and an external alarm port.

5. Think About Space

The catalogue lists saving floor space in small and crowded laboratories, running two different conditions side by side, and keeping sensitive samples apart from each other. Ask us for the outside dimensions before you plan the position.

Delivery, Installation And Warranty

Installation and operator training are included in the price. The warranty covers parts and labour, but not consumables, and runs for 1 year from installation or 15 months from the invoice date, whichever ends earlier. An optional 12-month AMC is available (see the service terms). Delivery takes 4 to 6 weeks from the date of advance payment. Every model is also available as -SS and -GMP versions. Documents supplied: IQ and OQ documents and third-party calibration certificates for the sensors and the controller, either NABL or non-NABL.

See the ELETOM79 dual chamber units page for the features, models and the full specification table. Tell us your application and we will recommend a model.