ELETOM79 Range
ELETOM79 Dual Chamber Refrigerators, Freezers, Stability Chambers And BOD Incubators
Two independent chambers in one unit, in the Pt Series and the Au Series. Supplied, installed and serviced in Karnataka by Alsin Technology Services, Bengaluru.

About ELETOM79 Dual Chamber Units
ELETOM79 dual chamber units stack two independent chambers in one instrument, so one footprint gives you two temperature zones. Each chamber can be a refrigerator, a freezer (−20 °C), a stability chamber or a BOD incubator, in 120 and 210 litre sizes, with its own temperature control and its own door.
Series
- Pt Series Combinations of 120 L and 210 L chambers
7 inch TFT colour touch display, 5-channel data recording with mapping, password-protected door lock and a UPS line for the controller - Au Series Combinations of 120 L and 210 L chambers
LCD display with 21 CFR compliance software, email alarm notifications and an external alarm port
Pt Series is the full-featured range. Au Series is the simpler range with a graphic display.
Applications
- Storing reagents and samples at 2 to 8 °C and −20 °C in one unit
- Running two different incubation or stability conditions side by side
- Saving floor space in small and crowded laboratories
- Keeping sensitive samples apart from each other
- Quality control, research and clinical laboratories
Typical uses, listed as a guide. Ask us to confirm that the instrument suits your process.

Pt Series
ELETOM79 Dual Chamber Units, Pt Series
Models: Combinations of 120 L and 210 L chambers
Key Features
- User-interactive and informative TFT colour touch display
- 21 CFR compliance software with PC interface
- Data recording with mapping (5 channels)
- Email notifications for alarms
- Process and event alarms
- Individual temperature controls for each chamber
- Dual door design for temperature retention
- Efficient low-noise compressor with CFC-free refrigerant
- Password-protected door locking mechanism
- High-grade PUF insulation
More Pt Series features from the catalogue
- In-built programmable timer
- Intelligent door-open sensing with alarm
- Robust build quality and compact footprint
- External port for alarm and acknowledgement
- Very user-friendly and informative user interface
- Date-time stamped process and event data recording
- Online and offline data recording with date-time stamping
- Environment-friendly instruments with low power consumption
- High-quality PUF insulation for better temperature retention
- Comprehensive alarm system (process deviations, door open, mains fail)
- 7 inch TFT, 65,536 colour touch screen with a touch life of more than one million operations
- Mains fail alarm: alarm on change-over from mains power to an alternate source (battery, inverter, etc.)
- GMP model available
- User-selectable options for combinations of dual chamber
- Capacities available for combinations: 120 L and 210 L

Au Series
ELETOM79 Dual Chamber Units, Au Series
Models: Combinations of 120 L and 210 L chambers
Key Features
- User-interactive and informative LCD display
- 21 CFR compliance software with PC interface
- Email notifications for alarms
- Process and event alarms
- Individual temperature controls for each chamber
- Dual door design for temperature retention
- Efficient low-noise compressor with CFC-free refrigerant
- High-grade PUF insulation
More Au Series features from the catalogue
- Intelligent door-open sensing with alarm
- Robust build quality and compact footprint
- 128 × 64 STN monochrome graphic display
- External port for alarm and acknowledgement
- Very user-friendly and informative user interface
- Comprehensive alarm system (process deviations, door open)
- High-quality PUF insulation for better temperature retention
- User-selectable options for combinations of dual chamber
- Capacities available for combinations: 120 L and 210 L
- GMP model available
Technical Specifications
Models And Sizes
| Top chamber | Bottom chamber |
|---|---|
| Refrigerator | Refrigerator |
| Refrigerator | Freezer (−20 °C) |
| Freezer (−20 °C) | Freezer (−20 °C) |
| Stability chamber | Stability chamber |
| BOD incubator | BOD incubator |
Construction Options
Every model is also available as an -SS or a -GMP version. The standard construction is in the specification table below.
- -SS: SS304 inner chamber and SS304 outer body.
- -GMP: SS316 inner chamber and SS304 outer body.
Tell us which version you need when you ask for a quote, and we will confirm the exact construction for your model.
Specification Details
| Specification | Pt Series | Au Series |
|---|---|---|
| Temperature range | Refrigerator 2 to 8 °C; freezer −20 °C; stability chamber 20 to 60 °C with humidity from ambient to 90 % RH; BOD incubator 10 to 60 °C | |
| Resolution | 0.1 °C | |
| Accuracy | ±1 °C, and ±3 % RH for the stability chamber | |
| Controller | 7 inch TFT colour touch, intelligent micro-PLC based, tuned PID temperature controller | Intelligent microprocessor based, tuned PID temperature controller |
| UPS supply | Separate UPS supply line dedicated to the controller for uninterrupted data recording | Not listed |
| Cooling compressor | Hermetically sealed, low-noise compressor with CFC-free refrigerant for efficient operation | |
| Defrosting | Freezer: user-programmable defrosting cycle, up to 1 month settable | |
| Air circulation | Air circulated vertically for uniform temperature distribution | |
| Inner chamber | SS304 grade | |
| Outer chamber | Powder-coated CRCA sheet | |
| Outer door | Outer side powder-coated CRCA sheet, inner side SS304 | |
| Inner door | Refrigerator, stability chamber and BOD incubator: toughened glass. Freezer: SS304 with insulation | |
| Insulation | High-grade rockwool or PUF insulation with a 65 mm gap between the inner and outer chamber | |
| Gasket | Silicone-based door gasket to avoid air leakage | |
| Validation port | On the side of the instrument, with a sealed cap for each chamber | |
| Trays | Removable stainless steel trays with user-adjustable spacing | |
| Operational safety | Safety door sensor cuts off operation to retain the temperature inside the chamber | |
| Electrical safety | Electro-magnetic interference filter, leakage current protector, fast-acting fuse and MCB | |
| Temperature safety | Factory-set auto electrical cut-off thermostat | |
| Documents | IQ and OQ documents and third-party calibration certificates for the sensors and the controller, either NABL or non-NABL | |
Actual power values depend upon the site voltage rating. Specifications are from the ELETOM79 catalogue 2025. Ask us to confirm details for your application.
Warranty on parts and labour and an optional 12-month AMC cover this instrument. See the service terms.
Delivery takes 4 to 6 weeks from the date of advance payment.
Read our guide: How to choose a dual chamber unit for a lab.
Quick Answers About ELETOM79 Dual Chamber Units
What Are ELETOM79 Dual Chamber Units?
ELETOM79 dual chamber units stack two independent chambers in one instrument, so one footprint gives you two temperature zones. Each chamber can be a refrigerator, a freezer (−20 °C), a stability chamber or a BOD incubator, in 120 and 210 litre sizes, with its own temperature control and its own door.
What Is The Difference Between The Pt Series And The Au Series Dual Chamber Units?
Pt Series (combinations of 120 L and 210 L chambers): 7 inch TFT colour touch display, 5-channel data recording with mapping, password-protected door lock and a UPS line for the controller. Au Series (combinations of 120 L and 210 L chambers): LCD display with 21 CFR compliance software, email alarm notifications and an external alarm port. The Pt Series is the full-featured range, and the Au Series is the simpler range.
What Are The Temperature Range And Accuracy Of ELETOM79 Dual Chamber Units?
Temperature range: Refrigerator 2 to 8 °C; freezer −20 °C; stability chamber 20 to 60 °C with humidity from ambient to 90 % RH; BOD incubator 10 to 60 °C. Resolution: 0.1 °C. Accuracy: ±1 °C, and ±3 % RH for the stability chamber.
What Are ELETOM79 Dual Chamber Units Used For?
The ELETOM79 catalogue lists these uses: storing reagents and samples at 2 to 8 °C and −20 °C in one unit; running two different incubation or stability conditions side by side; saving floor space in small and crowded laboratories; keeping sensitive samples apart from each other; quality control, research and clinical laboratories. These are listed as a guide, so ask us to confirm that the instrument suits your process.
Where Can I Buy ELETOM79 Dual Chamber Units In Bengaluru Or Karnataka?
Alsin Technology Services is the Karnataka dealer for ELETOM79 laboratory instruments. Our office is at 84/B, First Floor, Veerabhadreshwara Industrial Area, Herohalli, Bengaluru (Bangalore) 560091, and it is open Monday to Saturday, 9:30 AM to 5:30 PM. Call +91 9071262002 or request a quote online.
What Do I Get With An ELETOM79 Instrument From Alsin: Installation, Warranty And Delivery?
Installation and operator training are included in the price. The warranty covers parts and labour, but not consumables, and runs for 1 year from installation or 15 months from the invoice date, whichever ends earlier. An optional 12-month AMC is available. Delivery takes 4 to 6 weeks from the date of advance payment. See the service terms.
Page updated 22 November 2026.
Other ELETOM79 Instruments

Laboratory Refrigerator
Refrigerators with dual door design and programmable defrost, in the Pt Series and the Au Series.

Laboratory Incubator
Stackable or stand-alone incubators for ambient +7 °C to +65 °C, in the Pt Series and the Au Series.
Tell Us About Your Application
Share what you need to run and your lab’s power supply. We will recommend a model and send a quote.
Request a quoteChat on WhatsApp