A melting point apparatus is a scientific instrument used to determine the melting point of a substance.

programmable-melting-point-apparatus.png

VMP-AD(T)

Specifications:

• Melting Point of Three Samples & Boiling Point of one sample can be determined.

• Provision for Unknown/New product evaluation.

• Validation Program for known Melting Point samples.

• Audio note when Temperature approaches to Melting Point.

• Manual observation for Melting Point.

• Magnetic stirrer for uniform stirring.

• Testing Temperature range Ambient + 15°C to 300° C.

• Temperature Gradient 0.5° C, 1.0° C.

• Oil —Bath with heating Media as Silicon fluid.

• Four User Level based functionality: System Admin, Admin, Manager and Operator.

• Role Based Access Control.

• Login Screen to login onto software.

• Uniqueness of User Id.

• Results are authenticated by Operator with Date and Time Stamped.

• 7 Inch TFT color monitor with capacitive touch screen for easy programming.

• Attractive user interface with multicolor graphic widgets and icons for interactive communication.

• Embedded with high performance single board computer for speedy data processing.

• Provision to take data back- up directly on server or any other PC.

• Print report can be obtained through server printer.

MELTING/BOILING POINT APPARATUS

vmp-cm.jpg

VMP-CM

Specifications:
  • Equipped with color camera and color monitor to observe Melting Point with ease.

  • Validation Program for Standard samples.

  • 8 Operator names can be stored.

  • Graphic LCD Display to display all test parameters & test instructions.

  • Memory to store around 100 test records.

  • Facility for testing UNKNOWN sample.

  • Temperature range: Room temperature +2 °C - 300 °C.

  • Temperature resolution: 0.1 °C.

  • Heating rate: 1 °C/minute (Starts from set temperature – 10 °C).

  • Input: Tactile Keyboard + PS - 2 keyboard.

  • Printer Facility: Available.

MELTING/BOILING POINT APPARATUS

vmp-d.jpg

VMP-D /DS

Specifications:
  • The VMP – D / DS is suitable for accurate determination of melting point and melting range.

  • Heating rate can be precisely adjusted by an electronic controller.

  • No of capillary tubes: Up to 3 for Melting Point/ 1 for Boiling Point.

  • Temperature range: Room temperature +2 °C - 300 °C.

  • Accuracy: VMP D - 1 °C / VMP DS – 0.3 – 0.5 °C.

  • Temperature resolution: VMP D - 1 °C / VMP DS – 0.1 °C.

  • Temperature sensor: Pt – 100.

PRECISION DIGITAL MELTING/BOILING POINT APPARATUS

OTHER SET OF INSTRUMENTS

Friability Test Apparatus

vft-2d.jpg

Disintegration Test Apparatus

Disintegration Test Apparatus

Karl Fischer Titrator

Karl Fischer Titrator

Lab(mili-q) Water System

Ultrapure Water System

Liquid Handling 

pipette.png

Bottle Top Dispenser

Bottle Top Dispenser
bottom of page