top of page

        The Automatic Potentiometric Titrator is Micro-Controller Based Titrator designed for Aqueous, Non-Aqueous, Red-Ox, Karl Fischer and pH Titrations. This titrator is used in QA, QC and R&D labs in Pharmaceutical, Chemical, Petrochemical, Food and other industries.

 

Application : Potentiometric Titrator

  • Aqueous, Non-Aqueous and Red-Ox titrations.

  • TAN /TBN titrations as per various ASTM methods.

  • Assay determination in Pharma industry.

  • Ampicillin, Amoxycilin and penicillin Analysis.

  • Chloride and Bromide analysis.

  • Acid and Base Value as per ASTM methods in various products.

  • Di-Azotization titrations.

  • Iodine number and Saponification number.

  • Complexometric – EDTA titrations

  • Estimation of Iso-Cynate group

potentiometric_edited.png

AUTO/POT-I

DIGITAL AUTOMATIC POTENTIOMETRIC TITRATION APPARATUS

Specifications:
  • Suitable for Aqueous/Non-Aqueous and Red-Ox titrations.

  • Valve less Dispenser suitable to handle various Titrants.

  • Titrant can be changed within no time.

  • Cumbersome Piston Burette is eliminated for ease of operation.

  • No Refilling is necessary after every titration.

  • Eliminates the need of interchangeable burette for different titrants.

  • Supports two methods for Normality. Standard Sample and Volumetric.

  • Up to 10 Peaks can be determined in Multi Peak Mode.

  • Test method storage facility for 100 test methods.

  • Password protected data.

  • Built-in Volume Validation Facility.

  • PS-2 Keyboard (QWERTY Keyboard) Interface for easy alphanumeric data entry.

  • Three User Level based functionality: Admin, Manager and Operator.

  • Role Based Access Control.

  • Login Screen to login onto software.

  • Incorporated with User management Module for Account Setting, Editing etc.

  • Uniqueness of User Id.

  • Pass Word Management as per guidelines.

  • System Time-outs after idleness

  • The system tracks the print & re-prints with the audit trail.

  • Back-Up Folder Facility

  • PC Interface through Ethernet

  • Results are authenticated by Operator with Date and Time Stamped.

  • All user actions are recorded in Audit Trail with Date and Time Stamped.

  • System does not allow the editing of Audit trail.

potentiometric_edited.png

AUTO/POT-KF

DIGITAL AUTOMATIC POTENTIOMETRIC TITRATION APPARATUS

Specifications:
  • Combined instrument suitable for Potentiometric and Karl Fischer Titrations.

  • Supports both Water and DST method for Factor determination.

  • Valve less Dispenser suitable to handle various Titrants.

  • Titrant can be changed within no time.

  • Cumbersome Piston Burette is eliminated for ease of operation.

  • No Refilling is necessary after every titration.

  • Eliminates the need of interchangeable burette for different titrants.

  • Supports two methods for Normality. Standard Sample and Volumetric.

  • Error messages inform the problems regarding chemicals.

  • Results in Percentage, PPM and mg of H2O.

  • Range of Moisture Detection: 50 PPM to 100% with appropriate sample size.

  • Drift Control: Automatic Drift Compensation.

  • Error Messages to avoid wastage of chemicals.

  • Same as Model AUTO/POT - I with additional facility for Karl Fischer Titrations also.

  • Three User Level based functionality: Admin, Manager and Operator.

  • Role Based Access Control.

  • Login Screen to login onto software.

  • Incorporated with User management Module for Account Setting, Editing etc.

  • Uniqueness of User Id.

  • Pass Word Management as per guidelines.

  • System Time-outs after idleness

  • The system tracks the print & re-prints with the audit trail.

  • Back-Up Folder Facility

  • PC Interface through Ethernet

  • Results are authenticated by Operator with Date and Time Stamped.

  • All user actions are recorded in Audit Trail with Date and Time Stamped.

  • System does not allow the editing of Audit trail.

potentiometric_edited.png

AUTO/POT – KF/pH

DIGITAL AUTOMATIC POTENTIOMETRIC TITRATION APPARATUS

Specifications:
  • Combined instrument suitable for Potentiometric, Karl Fischer as well as pH Titrations.

  • pH range 0 -14 pH.

  • Temperature Compensation Facility.

  • pH Calibration by Three Buffers.

  • Suitable for determination of acidity of milk and milk products.

  • Valve less Dispenser suitable to handle various Titrants.

  • Titrant can be changed within no time.

  • Cumbersome Piston Burette is eliminated for ease of operation.

  • No Refilling is necessary after every titration.

  • Eliminates the need of interchangeable burette for different titrants.

  • Supports two methods for Normality. Standard Sample and Volumetric.

  • Same as Model AUTO/POT – KF with additional facility for pH Titrations also.

OTHER SET OF PRODUCTS 

Density Test Apparatus

vtap-II.jpg
digitab-1.jpg

Tablet Hardness Tester

Karl Fischer Titrator

vm-ex.png

Microwave Synthesis

Picture2.jpg

Electronic Pipette

LH-ePipPicus-11118-09992eb1e2.jpg
wheaton.jpg

Serum Bottles

bottom of page